Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Stem Cell Res Ther ; 13(1): 407, 2022 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-35941707

RESUMO

BACKGROUND: Large area skin trauma has always been a great challenge for both patients and clinicians. Exosomes originating from human adipose-derived mesenchymal stem cells (hADSCs) have been a novel promising cell-free treatment in cutaneous damage repair. Nevertheless, the low retention rate of exosomes post-transplantation in vivo remains a significant challenge in clinical applications. Herein, we purposed to explore the potential clinical application roles of hADSCs-Exos encapsulated in functional PF-127 hydrogel in wound healing. METHODS: hADSCs-Exos were isolated from human hADSCs by ultracentrifugation. An injectable, biocompatible, and thermo-sensitive hydrogel Pluronic F-127 hydrogel was employed to encapsulate allogeneic hADSCs-Exos, and this complex was topically applied to a full-thickness cutaneous wound in mice. On different days post-transplantation, the mice were sacrificed, and the skin tissue was excised for histological and immunohistochemical analysis. RESULTS: Compared with hADSCs-Exos or PF-127 only, PF-127/hADSCs-Exos complexes enhanced skin wound healing, promoted re-epithelialization, increased expression of Ki67, α-SMA, and CD31, facilitated collagen synthesis (Collagen I, Collagen III), up-regulated expression of skin barrier proteins (KRT1, AQP3), and reduced inflammation (IL-6, TNF-α, CD68, CD206). By using PF-127/hADSCs-Exos complexes, hADSCs-Exos can be administrated at lower doses frequency while maintaining the same therapeutic effects. CONCLUSION: Administration of hADSCs-Exos in PF-127 improves the efficiency of exosome delivery, maintains the bioactivity of hADSCs-Exos, and optimizes the performance of hADSCs-Exos. Thus, this biomaterial-based exosome will be a promising treatment approach for the cutaneous rejuvenation of skin wounds.


Assuntos
Exossomos , Células-Tronco Mesenquimais , Animais , Colágeno/metabolismo , Exossomos/metabolismo , Humanos , Hidrogéis/farmacologia , Células-Tronco Mesenquimais/metabolismo , Camundongos , Poloxâmero/metabolismo , Poloxâmero/farmacologia , Cicatrização
2.
Stem Cell Res Ther ; 12(1): 257, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33933157

RESUMO

BACKGROUND: Cutaneous wound healing and regeneration have become a recognized health challenge in the world, which causes severe damage to the mental and physical health of patients. Human adipose-derived mesenchymal stem cells (hADSC) play an essential role in wound healing via their paracrine function. Exosomes secreted by hADSC may contribute to this progress. In this study, we investigated the potential clinical application roles of hADSC and hADSC-derived exosomes (hADSC-Exo) in cutaneous wound healing. METHODS: hADSC-Exo was isolated from human hADSC by ultracentrifugation. Mice were subjected to a full-thickness skin biopsy experiment and treated with either control vehicle or hADSC or hADSC-Exo by smearing administration (sm) or subcutaneous administration (sc) or intravenous administration (iv). The efficacy of hADSC and hADSC-Exo on wound healing was evaluated by measuring wound closure rates, histological analysis. RESULTS: Combined application of local hADSC-Exo smearing and hADSC/hADSC-Exo intravenous administration offered the additional benefit of promoting wound healing, accelerating re-epithelialization, reducing scar widths, and enhancing angiogenesis and collagen synthesis. Either topical application of hADSC-Exo or systemic administration with hADSC/hADSC-Exo appeared more effective in stimulating cell proliferation, inhibiting cell apoptosis and inflammation, and promoting skin elasticity and barrier integrity, with increased genes expression of PCNA, VEGF, collagen III, Filaggrin, Loricrin, and AQP3, with decreased genes expression of TNF-alpha. CONCLUSION: Our findings suggest that the combined administration of hADSC/hADSC-Exo can facilitate cutaneous wound healing and reduce scar formation. These data provide the first evidence for the feasibility of smearing of hADSC-Exo as a cell-free therapy in treating cutaneous wounds, and the potential clinical value of combined administration of hADSC/hADSC-Exo.


Assuntos
Exossomos , Células-Tronco Mesenquimais , Animais , Proliferação de Células , Proteínas Filagrinas , Humanos , Camundongos , Pele , Cicatrização
3.
J Korean Neurosurg Soc ; 64(2): 297-308, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33626856

RESUMO

OBJECTIVE: Shunt infection is a common complication while treating hydrocephalus. The antibiotic-impregnated shunt catheter (AISC) was designed to reduce shunt infection rate. A meta-analysis was conducted to study the effectiveness of AISCs in reduction of shunt infection in terms of age, follow-up time and high-risk patient population. METHODS: This study reviewed literature from three databases including PubMed, EMBASE, and Cochrane Library (from 2000 to March 2019). Clinical studies from controlled trials for shunt operation were included in this analysis. A subgroup analysis was performed based on the patient's age, follow-up time and high-risk population. The fixed effect in RevMan 5.3 software (Cochrane Collaboration) was used for this meta-analysis. RESULTS: This study included 19 controlled clinical trials including 10105 operations. The analysis demonstrated that AISC could reduce the infection rate in shunt surgery compared to standard shunt catheter (non-AISC) from 8.13% to 4.09% (odds ratio [OR], 0.48; 95% confidence interval [CI], 0.40-0.58; p=0.01; I2=46%). Subgroup analysis of different age groups showed that AISC had significant antimicrobial effects in all three groups (adult, infant, and adolescent). Follow-up time analysis showed that AISC was effective in preventing early shunt infections (within 6 months after implant). AISC is more effective in high-risk population (OR, 0.24; 95% CI, 0.14-0.40; p=0.60; I2=0%) than in general patient population. CONCLUSION: The results of meta-analysis indicated that AISC is an effective method for reducing shunt infection. We recommend that AISC should be considered for use in infants and high-risk groups. For adult patients, the choice for AISC could be determined based on the treatment cost.

4.
Br J Neurosurg ; 34(4): 388-396, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32233810

RESUMO

Objective: Meta-analysis to evaluate complications in the use of autogenous bone and bone substitutes and to compare bone substitutes, specifically HA, polyetheretherketone (PEEK) and titanium materials.Methods: Search of PubMed, Cochrane, Embase and Google scholar to identify all citations from 2010 to 2019 reporting complications regarding materials used in cranioplasty.Results: 20 of 2266 articles met the inclusion criteria, including a total of 2913 patients. The odds of overall complication were significantly higher in the autogenous bone group (n = 214/644 procedures, 33.2%) than the bone substitute groups (n = 116/436 procedures, 26.7%, CI 1.29-2.35, p < 0.05). In bone substitutes groups, there was no significant difference in overall complication rate between HA and Ti (OR, 1.2; 95% CI, 0.47-3.14, p = 0.69). PEEK has lower overall complication rates (OR, 0.51; 95% CI, 0.30-0.87, p = 0.01) and lower implant exposure rates (OR, 0.17; 95% CI, 0.06-0.53, p = 0.002) than Ti, but there was no significant difference in infection rates and postoperative hematoma rates.Conclusions: Cranioplasty is associated with high overall complication rates with the use of autologous bone grafts compared with bone substitutes. PEEK has a relatively low overall complication rates in substitutes groups, but still high infection rates and postoperative hematoma rates. Thus, autologous bone grafts should only be used selectively, and prospective long-term studies are needed to further refine a better material in cranioplasty.


Assuntos
Procedimentos de Cirurgia Plástica , Crânio/cirurgia , Transplante Ósseo , Humanos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Próteses e Implantes/efeitos adversos
5.
Acta Biomater ; 97: 657-670, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31401346

RESUMO

In the present study, a novel biodegradable Zn-0.8Cu coronary artery stent was fabricated and implanted into porcine coronary arteries for up to 24 months. Micro-CT analysis showed that the implanted stent was able to maintain structural integrity after 6 months, while its disintegration occurred after 9 months of implantation. After 24 months of implantation, approximately 28 ±â€¯13 vol% of the stent remained. Optical coherence tomography and histological analysis showed that the endothelialization process could be completed within the first month after implantation, and no inflammation responses or thrombosis formation was observed within 24 months. Cross-section analysis indicated that the subsequent degradation products had been removed in the abluminal direction, guaranteeing that the strut could be replaced by normal tissue without the risk of contaminating the circulatory system, causing neither thrombosis nor inflammation response. The present work demonstrates that the Zn-0.8Cu stent has provided sufficient structural supporting and exhibited an appropriate degradation rate during 24 months of implantation without degradation product accumulation, thrombosis, or inflammation response. The results indicate that the Zn-0.8Cu coronary artery stent is promising for further clinical applications. STATEMENT OF SIGNIFICANCE: Although Zn and its alloys have been considered to be potential candidates of biodegradable metals for vascular stent use, by far, no Zn-based stent with appropriate medical device performance has been reported because of the low mechanical properties of zinc. The present work presents promising results of a Zn-Cu biodegradable vascular stent in porcine coronary arteries. The Zn-Cu stent fabricated in this work demonstrated adequate medical device performance both in vitro and in vivo and degraded at a proper rate without safety problems induced. Furthermore, large animal models have more cardiovascular similarities as humans. Results of this study may provide further information of the Zn-based stents for translational medicine research.


Assuntos
Implantes Absorvíveis , Vasos Coronários , Teste de Materiais , Stents , Tomografia de Coerência Óptica , Animais , Cobre/química , Cobre/metabolismo , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Suínos , Fatores de Tempo , Zinco/química , Zinco/metabolismo
6.
J Vasc Access ; 20(5): 524-529, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30596472

RESUMO

INTRODUCTION: Ultrasound-guided venipuncture and tip location by intracavitary electrocardiogram have many advantages during the insertion of peripherally inserted central catheters, both in terms of safety and cost-effectiveness. Recently, a new tip-conductive peripherally inserted central catheters and new Doppler ultrasound device integrated with intracavitary electrocardiogram have been introduced into clinical practice in China. A randomized multicenter study (clinical trial no. NCT03230357) was performed to verify the feasibility and accuracy of intracavitary electrocardiogram, as performed with this new peripherally inserted central catheters and device. METHODS: Our study enrolled a total of 2250 adult patients in 10 different Chinese hospitals. The patients were randomly assigned to either the study group (intracavitary electrocardiogram) or the control group (anatomical landmark guidance) in a 2:1 allocation. Ultrasound was used in both groups for venipuncture and tip navigation. All patients underwent chest X-ray after the procedure to verify the position of the catheter tip. RESULTS: No insertion-related complications were reported in either group. In the study group, first-attempt successful tip location was 91.7% (95% confidence interval: 90.3%-93.1%), significantly higher than 78.9% (95% confidence interval: 76.0%-81.9%) observed in the control group (p < 0.001). As evaluated by post-procedural chest X-ray, tip location in the study group had a sensitivity of 99.3% (95% confidence interval: 98.8%-99.7%), significantly higher than 86.8% (95% confidence interval: 84.4%-89.2%) observed in the anatomical landmark group (p < 0.001). CONCLUSION: These results indicated that during peripherally inserted central catheters insertion in adult patients, tip location with intracavitary electrocardiogram guidance, as carried out by a new tip-conductive peripherally inserted central catheters and intracavitary electrocardiogram integrated ultrasound device, was more effective and more accurate than tip location using anatomical landmarks.


Assuntos
Cateterismo Periférico/instrumentação , Cateteres de Demora , Pressão Venosa Central , Eletrocardiografia/instrumentação , Transdutores , Ultrassonografia Doppler/instrumentação , Ultrassonografia de Intervenção/instrumentação , Idoso , Pontos de Referência Anatômicos , Cateterismo Periférico/efeitos adversos , China , Eletrocardiografia/métodos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...